LG HB2 2S6P Battery Pack

ICR18650HB2, 9Ah, 7.3V, 10A

main images

LG HB2 2S6P Specifications

Configuration 2S6P
Cell LG ICR18650HB2
Cell size 18650
Cell chemistry
Weight 0.6 kg
Length 12.21 cm
Width 2.24 cm
Height 13.59 cm
Charge voltage 8.40 V
End voltage 4.00 V
Capacity 9000 mAh
Maximum continuous discharge current 10 A
Charge current 5 A
Watts 73 W
Energy 66 Wh
Volumetric energy density 325.41 Wh/L
Gravimetric energy density 114.58 Wh/kg
Charge time 5 hours
Operating temperature -20 ~ 75 °C

Size Variations

LG HB2 2S6P 1-layer in parablock 3x2

Length 122.04 mm
Width 42.54 mm
Height 67.84 mm

LG HB2 2S6P 1-layer in parablock 1x6

Length 41.2 mm
Width 123.3 mm
Height 67.8 mm

LG HB2 2S6P 1-layer in parablock 6x1

Length 243.2 mm
Width 22.3 mm
Height 67.8 mm

LG HB2 2S6P 2-layer in parablock 2x3

Length 41.2 mm
Width 62.7 mm
Height 135.8 mm

LG HB2 2S6P 2-layer in parablock 3x2

Length 61.4 mm
Width 42.5 mm
Height 135.8 mm

LG HB2 2S6P 2-layer in parablock 1x6

Length 21.06 mm
Width 123.36 mm
Height 135.86 mm

LG HB2 2S6P 2-layer in parablock 6x1

Length 122.06 mm
Width 22.36 mm
Height 135.86 mm

Calculations

Q. How to calculate the voltage for 2S6P LG HB2 pack?

A. Take the nominal voltage of the LG HB2 (3.65V) and multiply it by series connections (2) for a total of 7.30V.

Q. How to calculate the capacity and current for 2S6P LG HB2 pack?

A. Take the nominal capacity of the LG HB2 (1.50Ah) and max. continuous discharge current (30 A) and multiply them by the parallel connections (6) for a total of 9.00Ah and 180A.

Built by Voltaplex Energy

We believe accessible battery automation software is critical for fighting climate change. Voltaplex can manufacture packs built with Voltx.ai software.