LG HB2 3S18P Battery Pack

ICR18650HB2, 27Ah, 10.95V, 10A

main images

LG HB2 3S18P Specifications

Configuration 3S18P
Cell LG ICR18650HB2
Cell size 18650
Cell chemistry
Weight 2.6 kg
Length 2.11 cm
Width 36.58 cm
Height 20.39 cm
Charge voltage 12.60 V
End voltage 6.00 V
Capacity 27000 mAh
Maximum continuous discharge current 10 A
Charge current 5 A
Watts 110 W
Energy 296 Wh
Volumetric energy density 324.32 Wh/L
Gravimetric energy density 114.20 Wh/kg
Charge time 5 hours
Operating temperature -20 ~ 75 °C

Size Variations

LG HB2 3S18P 1-layer in parablock 3x6

Length 182.7 mm
Width 123.4 mm
Height 67.9 mm

LG HB2 3S18P 1-layer in parablock 6x3

Length 364.46 mm
Width 62.76 mm
Height 67.86 mm

LG HB2 3S18P 1-layer in parablock 1x18

Length 61.46 mm
Width 365.76 mm
Height 67.86 mm

LG HB2 3S18P 1-layer in parablock 9x2

Length 546.24 mm
Width 42.54 mm
Height 67.84 mm

LG HB2 3S18P 1-layer in parablock 18x1

Length 1091.6 mm
Width 22.3 mm
Height 67.8 mm

LG HB2 3S18P 2-layer in parablock 2x9

Length 81.7 mm
Width 184 mm
Height 135.9 mm

LG HB2 3S18P 2-layer in parablock 3x6

Length 122.1 mm
Width 123.4 mm
Height 135.9 mm

LG HB2 3S18P 2-layer in parablock 6x3

Length 243.3 mm
Width 62.8 mm
Height 135.9 mm

LG HB2 3S18P 2-layer in parablock 9x2

Length 364.5 mm
Width 42.6 mm
Height 135.9 mm

LG HB2 3S18P 2-layer in parablock 1x18

Length 41.3 mm
Width 365.8 mm
Height 135.9 mm

LG HB2 3S18P 2-layer in parablock 18x1

Length 728.06 mm
Width 22.36 mm
Height 135.86 mm

LG HB2 3S18P 3-layer in parablock 2x9

Length 41.3 mm
Width 184 mm
Height 203.9 mm

LG HB2 3S18P 3-layer in parablock 3x6

Length 61.5 mm
Width 123.4 mm
Height 203.9 mm

LG HB2 3S18P 3-layer in parablock 6x3

Length 122.1 mm
Width 62.8 mm
Height 203.9 mm

LG HB2 3S18P 3-layer in parablock 9x2

Length 182.7 mm
Width 42.6 mm
Height 203.9 mm

LG HB2 3S18P 3-layer in parablock 18x1

Length 364.5 mm
Width 22.4 mm
Height 203.9 mm

LG HB2 3S18P 3-layer in parablock 1x18

Length 21.1 mm
Width 365.8 mm
Height 203.9 mm

Calculations

Q. How to calculate the voltage for 3S18P LG HB2 pack?

A. Take the nominal voltage of the LG HB2 (3.65V) and multiply it by series connections (3) for a total of 10.95V.

Q. How to calculate the capacity and current for 3S18P LG HB2 pack?

A. Take the nominal capacity of the LG HB2 (1.50Ah) and max. continuous discharge current (30 A) and multiply them by the parallel connections (18) for a total of 27.00Ah and 540A.

Built by Voltaplex Energy