Sanyo F 9S4P Specifications
Configuration | 9S4P |
Cell | Sanyo UR18650F |
Cell size | 18650 |
Cell chemistry | |
Weight | 1.7 kg |
Length | 8.16 cm |
Width | 2.23 cm |
Height | 61.00 cm |
Charge voltage | 37.80 V |
End voltage | 24.75 V |
Capacity | 10000 mAh |
Maximum continuous discharge current | 10 A |
Charge current | 5 A |
Watts | 333 W |
Energy | 333 Wh |
Volumetric energy density | 555.06 Wh/L |
Gravimetric energy density | 196.81 Wh/kg |
Charge time | 5 hours |
Operating temperature | -20 ~ 60 °C |
Size Variations
Sanyo F 9S4P 1-layer in parablock 2x2
Length | 364.44 mm |
Width | 42.54 mm |
Height | 67.64 mm |
Sanyo F 9S4P 1-layer in parablock 4x1
Length | 728 mm |
Width | 22.3 mm |
Height | 67.6 mm |
Sanyo F 9S4P 2-layer in parablock 2x2
Length | 202.9 mm |
Width | 42.6 mm |
Height | 135.5 mm |
Sanyo F 9S4P 2-layer in parablock 1x4
Length | 101.9 mm |
Width | 83 mm |
Height | 135.5 mm |
Sanyo F 9S4P 2-layer in parablock 4x1
Length | 404.86 mm |
Width | 22.36 mm |
Height | 135.46 mm |
Sanyo F 9S4P 3-layer in parablock 2x2
Length | 122.06 mm |
Width | 42.56 mm |
Height | 203.26 mm |
Sanyo F 9S4P 3-layer in parablock 1x4
Length | 61.46 mm |
Width | 82.96 mm |
Height | 203.26 mm |
Sanyo F 9S4P 3-layer in parablock 4x1
Length | 243.3 mm |
Width | 22.4 mm |
Height | 203.3 mm |
Sanyo F 9S4P 5-layer in parablock 2x2
Length | 81.66 mm |
Width | 42.56 mm |
Height | 338.86 mm |
Sanyo F 9S4P 5-layer in parablock 1x4
Length | 41.26 mm |
Width | 82.96 mm |
Height | 338.86 mm |
Sanyo F 9S4P 5-layer in parablock 4x1
Length | 162.5 mm |
Width | 22.4 mm |
Height | 338.9 mm |
Sanyo F 9S4P 9-layer in parablock 2x2
Length | 41.16 mm |
Width | 42.46 mm |
Height | 609.96 mm |
Sanyo F 9S4P 9-layer in parablock 1x4
Length | 21 mm |
Width | 82.9 mm |
Height | 610 mm |
Sanyo F 9S4P 9-layer in parablock 4x1
Length | 81.6 mm |
Width | 22.3 mm |
Height | 610 mm |
Calculations
Q. How to calculate the voltage for 9S4P Sanyo F pack?
A. Take the nominal voltage of the Sanyo F (3.7V) and multiply it by series connections (9) for a total of 33.30V.
Q. How to calculate the capacity and current for 9S4P Sanyo F pack?
A. Take the nominal capacity of the Sanyo F (2.50Ah) and max. continuous discharge current (5 A) and multiply them by the parallel connections (4) for a total of 10.00Ah and 20A.